Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 6 de 6
Filter
Add filters








Language
Year range
1.
Article | IMSEAR | ID: sea-216388

ABSTRACT

Adverse cardiac remodeling refers to progressive structural and functional modifications in the heart because of increased wall stress in the myocardium, loss of viable myocardium, and neurohormonal stimulation. The guideline-directed medical therapy for Heart failure (HF) includes Angiotensin receptor-neprilysin inhibitor (ARNI) (sacubitril/valsartan), ?-blockers, sodium-glucose co-transporter 2 (SGLT2) inhibitors, and mineralocorticoid receptor antagonists (MRA). ARNI is under-prescribed in India despite its attractive safety and efficacy profile. Therefore, the consensus discusses objectives and topics related to ARNI in the management of cardiac remodeling, and experts shared their views on the early timely intervention of effective dosage of ARNI to improve the diagnosis and enhance mortality and morbidity benefits in cardiac reverse remodeling (CRR).

2.
Ann Card Anaesth ; 2019 Apr; 22(2): 194-198
Article | IMSEAR | ID: sea-185878

ABSTRACT

Introduction: Intraoperative trans-esophageal echocardiography (TEE) has been found to underestimate severity of aortic stenosis (AS) compared to trans-thoracic echo (TTE). We conducted a prospective study comparing pre induction TTE and intra operative TEE grading of AS in patients posted for aortic valve replacement surgeries. Methods: Sixty patients with isolated AS who were undergoing aortic valve replacement were enrolled in our study. Baseline TTE was done and after induction of anesthesia, TEE was done. Mean gradient across aortic valve, peak jet velocity, aortic valve area (AVA) by continuity equation and dimensionless index (DI) were assessed in both. Results: Mean gradient decreased from 56.4 in TTE to 39.8 mm Hg in TEE leading to underestimation of AS in 74.5% of patients (P < 0.0). Mean of peak jet velocity also decreased from 500 in TTE to 386cm/s in TEE (P < 0.01). In 76 % of patients this led to reduction of AS grade from severe to moderate. Mean AVA was 0.67 cm2 in TTE and 0.69 cm2 in TEE. Though there was 0.02 cm2 increase, it was not statistically significant (P = 0.07). All the patients remained as severe AS in TEE. DI mean was 0.19 in both TTE and TEE (P = 0.14).It led to underestimation of severity in 6% of patients in TEE. Conclusion: Our study shows that AVA measurement by continuity equation and DI are reliable in grading aortic stenosis while performing intraoperative TEE. Mean gradient and jet velocity can be significantly reduced.

3.
Ann Card Anaesth ; 2016 Jan; 19(1): 142
Article in English | IMSEAR | ID: sea-172309
4.
Ann Card Anaesth ; 2015 Oct; 18(4): 613-615
Article in English | IMSEAR | ID: sea-165282
SELECTION OF CITATIONS
SEARCH DETAIL